01 · Client Challenge

What needed to be solved

The residential property suffered from frequent grid power instability and prolonged outages, causing severe disruption to household appliances and relying heavily on expensive generator operation. The client required a quiet, reliable, and maintenance-free clean energy solution capable of sustaining essential domestic loads day and night..

02 · Solution Delivered

How Humelix responded

The HUMELIX LIMITED engineering team designed and executed a clean roof-mount installation for a 10-panel (4.5 kWp) solar PV array positioned for optimal daily irradiance. On the indoor distribution wall, our team installed a wall-mounted LiFePO4 battery pack, a 60A MPPT charge controller, and a robust 3.5 kVA Wakatek Pure Sine Wave inverter. We integrated dedicated DC/AC distribution panels featuring Surge Protection Devices (SPD), Double-Pole MCBs, and earth-fault protection to guarantee system longevity and maximum safety.

03 · Result / Outcome

The operational result

Successfully transitioned the residence to a dependable, continuous solar power supply. Grid dependence and monthly fuel costs were reduced by over 85%, while providing clean, stable single-phase power (230\text{V}, up to 15.2\text{A} continuous load) without voltage drops or unexpected interruptions.

Equipment / Materials

What supported the work

Panels: 10 × 450W High-Efficiency Monocrystalline Solar Panels ​Max Array Output: 4,500 \text{ Watts} DC power

Safety Approach

How the site was controlled

Rigorous safety protocols observed during roof mounting and ladder positioning.
​Full deployment of technician PPE (safety helmets, high-visibility vests, insulated boots, and gloves).
​Pre-commissioning testing, including PV string open-circuit voltage (V_{oc}) verification, polarity checks, short-circuit current (I_{sc}) testing, and AC insulation resistance testing prior to system activation.

Technical reviewSite requirements, service scope and practical constraints are reviewed before recommendations.
Safe deliveryWork is aligned with safety controls, clean execution and client-site protection.
Handover supportCompleted work is closed with guidance, next steps and aftercare awareness.
Extended Outcome

Operational result

Conducted full circuit-balancing checks across the residence's distribution board and handed over a customized energy-management guide to the owner, outlining load prioritization techniques during non-sunny hours to prolong battery lifespan.